Đầu báo hồng ngoại TAKEX PA-5312(E)
- High performance dual twin element optical unit.
- High density detection area.
- Slight motion detection-selectable twin/quad sensing.
- Self-test function.
- Built-in alarm memory.
- Trouble alarm.
Đầu báo hồng ngoại TAKEX PA-5312(E)
Thông số kỹ thuật
Model PA-5312(E)
Product type Passive infrared sensor
Detection system Passive infrared (QUAD)
Coverage Wide angle: 12m (40ft) max.
Sensitive zone 72 (18 pairs)
Supply voltage 9.5 to 30VDC (non-polarity)
Current consumption NC contact: 25mA max. / NO contact: 35mA max.
Alarm output Dry contact relay (NO/NC changeover)
Reset: approx. 2 sec, 30V (AC/DC) 0.25A
(Protective resistor 3.3Ω)
Tamper output Dry contact relay (N/C)
Open when cover or body is detached
30V 0.1A max.
Alarm memory Auto-reset memory: 3 mins. flashing, 47 mins lighting
Manual memory: memory disabled/indication/reset control using terminal 8
Slight motion detection Sensitive zone: 36 pairs
Alarm LED (RED) Blinking (every 0.5sec): Warm-up
Lighting (approx. 2 sec): Alarm
Blinking (every 0.25sec): Trouble indication
Continuous lighting: Trouble alarm
(Disabled is LED except trouble indication)
Memory LED (YELLOW) Blinking: Memory activated
Lighting: Memory indicated
Trouble indication Alarm contact checking whenever an alrm outputs
Operation: Trouble indication
Trouble signal Unit trouble: Monitoring inner circuit and wiring damage
Operation: Trouble alarm
Low voltage troouble: Monitoring low voltage
Operation: Trouble alarm
Positioning trouble: monitoring failure to replace view finder
Operation: Trouble alarm
Ambient temperature -10°C to +55°C (+14°F to +131°F)
Mounting position Indoor ceiling / wall
Wiring connections Terminals
Weight 250g (8.75oz)
Appearance Body: ABS resin
Đang cập nhật...