-Universal AC input/ Full range.
-Protections: Short circuit/ Overload/ Over voltage/ Over temperature.
-Cooling by free air convection.
-Can be installed on DIN rail TS-35/ 7.5 or 15.
-UL 508 (industrial control equipment) approved.
-EN61000-6-2 (EN50082-2) industrial immunity level.
-100% full load burn-in test.
-NDR-120-48 is one economical slim 120W DIN rail power supply series, adapter to be installed on TS-35/ 7.5 or TS-35/15 mounting rails. The body is designed 40mm in width, which allows space saving inside the cabinets.
-The entire series adopts the full range AC input from 90VAC to 264VAC and conforms to EN61000-3-2, the norm the European Union regulates for harmonic current.
-NDR-120-48 is designed with metal housing that enhances the unit’s power dissipation. With working efficiency up to 89%, the entire series can operate at the ambient temperature between -20ºC and 70ºC under air convection. It is equipped with constant current mode for over-load protection, fitting various inductive or capactive applications. The complete protection functions and relevant certificates for industrial control apparatus (UL508, TUV EN60950-1 and etc.) make NDR-120-48 a very competitive power supply solution for industrial applications.
MODEL |
NDR-120-48 |
|
OUTPUT |
DC VOLTAGE |
48VDC |
RATED CURRENT |
2.5A |
|
CURRENT RANGE |
0 ~ 2.5A |
|
RATED POWER |
120W |
|
RIPPLE & NOISE (max.) Note.2 |
150mVp-p |
|
VOLTAGE ADJ. RANGE |
48 ~ 55V |
|
VOLTAGE TOLERANCE Note.3 |
±1.0% |
|
LOAD REGULATION |
±1.0% |
|
SETUP, RISE TIME |
2500ms, 60ms/115VAC at full load |
|
HOLD UP TIME (Typ.) |
10ms/115VAC at full load |
|
INPUT |
VOLTAGE RANGE Note.6 |
127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)] |
FREQUENCY RANGE |
47 ~ 63Hz |
|
AC CURRENT (Typ.) |
1.3A/230VAC |
|
INRUSH CURRENT (Typ.) |
35A/230VAC |
|
LEAKAGE CURRENT |
<1mA / 240VAC |
|
PROTECTION |
OVERLOAD |
105 ~ 130% rated output power. 105 ~ 130% rated output power |
OVER VOLTAGE |
56 ~ 65V. Protection type: Shut down o/p voltage, re-power on to recove |
|
OVER TEMPERATURE |
Shut down o/p voltage, re-power on to recover |
|
ENVIRONMENT |
WORKING TEMP. |
-20º ~ +70ºC (Refer to 'Derating Curve') |
WORKING HUMIDITY |
20 ~ 95% RH non-condensing |
|
STORAGE TEMP., HUMIDITY |
-40º ~ +85ºC , 10 ~ 95% RH |
|
TEMP. COEFFICIENT |
±℃ ℃ 0.03%/ (0 ~ 50ºC) |
|
VIBRATION |
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
|
SAFETY &EMC(Note 4) |
SAFETY STANDARDS |
UL508, TUV EN60950-1 approved |
WITHSTAND VOLTAGE |
O/P-FG:0.5KVAC |
|
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25 / 70% RH |
|
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A |
|
OTHERS |
MTBF |
456.3K hrs min. MIL-HDBK-217F (25ºC) |
DIMENSION |
40 x 125.2 x 113.5mm |
|
WEIGHT |
13kg |