Model |
OLS6000ERT6UA |
General |
UPS Topology |
Online Double Conversion |
Energy Saving Technology |
Online ECO Mode Eciency > 96% |
Active PFC Compatibility |
Yes |
Parallel Expansion |
4 |
Input |
Compatible with Generators |
Yes |
Nominal Input Voltage |
230VAC |
Input Voltage Range |
110 ~ 276 VAC |
Adjustable Voltage Range |
0 ~ 80% load 110 ~ 276 Vac 0 ~ 100% load 176 ~ 276 Vac |
Input Frequency |
50Hz ± 5 60Hz ± 6 |
Input Frequency Detection |
Auto-sensing |
Rated Input Current |
27.3A |
Input Power Factor |
0.99 |
Input Connector Type |
Hardwire Terminal Block |
Output |
Capacity |
6000VA |
Capacity |
5400W |
On Battery Waveform |
Pure Sine Wave |
On Battery Voltage |
208 ± 1% 220 ± 1% 230 ± 1% 240 ± 1% |
Output Voltage Setting |
Configuration |
On Battery Frequency |
50Hz ± 0.1% 60Hz ± 0.1% |
Output Frequency Setting |
Configuration |
Power Factor |
0.9 |
ECO voltage mode |
± 10% |
Overload Protection |
Internal Current Limiter, Circuit Breaker, Fuse |
Overload Protection (Line Mode) |
105 ~ 125% Load for 1 min, 125 ~ 135% Load for 30 sec, 135 ~ 150% Load for 1 sec,> 150% Load Immediately |
Overload Protection (Battery Mode) |
105 ~ 125% Load for 1 min, 125 ~ 135% Load for 30 sec,> 135% Load Immediately |
Overload Protection (Bypass Mode) |
125 ~ 150% Load for 1 min, 150 ~ 170% Load for 10 sec,> 170% Load for 1 sec |
Harmonic distortion (Linear load) |
THD <2% |
Harmonic distortion (Non-linear load) |
THD <5% |
Bypass In |
Auto Skip |
Socket (s) – Total |
1 |
Normal Switching Time |
0 |
Battery |
Runtime at Half Load |
9.3 min |
Runtime at Full Load |
2.5 min |
Typical Recharge Time |
4 hours |
Maximum Charge Current |
1A |
Smart Battery Management (SBM) |
Yes |
User-replaceable |
No |
Battery Type |
Sealed Lead-acid |
Extended Battery Module (EBM) |
BPSE192V75ART3U |
Maximum Number of EBMs |
3 |
Surge protection & Filtering |
Surge Suppression |
445J |
EMI/RFI Filtration |
Yes |
Management & Communications |
LCD Panel |
Yes |
LCD Orientation |
Rotatable LCD – via Setting |
HID Compliant USB Port(s) |
1 |
Serial Port |
RS232 |
Dry Switch (with Relay) |
Optional |
Emergency Power Off (EPO) Port |
Yes |
Power Management Software |
PowerPanel® Business (Recommended) |
SNMP/HTTP Remote Monitoring |
Yes - with RMCARD205 option |
Physical |
Form Factor |
Rackmount, Tower |
Others |
Dimensions (WxHxD) |
438 x 130.5 x 480 mm |
Weight |
13.8kg |
Installed Rack Height |
3U |
Operating Temperature |
0 ~ 40°C |
Operating Relative Humidity (Non-condensing) |
20 ~ 90% |
Online Thermal Dissipation |
1603 BTU/hr |