Power Adapter 54VDC Vivotek HLG-240H-54
-HLG-240H-54 series is a 240W AC/DC LED driver featuring the dual mode constant voltage and constant current output.
-HLG-240H-54 operates from 90 305VAC and offers models with different rated voltage ranging ~ between 12V and 54V.
-High efficiency up to 93.5%, with the fanless design, the entire series is able to operate for -40 ~ +90 ℃ ℃ case temperature under free air convection.
-The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications.
-HLG-240H-54 is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
MODEL |
HLG-240H-54 |
|
OUTPUT |
VOLTAGE |
54VDC |
CONSTANT CURRENT REGION Note.4 |
27 ~ 54V |
|
RATED CURRENT |
4.45A |
|
RATED POWER |
240.3W |
|
RIPPLE & NOISE (max.) Note.2 |
350mVp-p |
|
VOLTAGE ADJ. RANGE |
Adjustable for A/C-Type only (via built-in potentiometer). |
|
50 ~ 57V |
||
CURRENT ADJ. RANGE |
Adjustable for A/C-Type only (via built-in potentiometer). 50 ~ 57V |
|
CURRENT ADJ. RANGE |
Adjustable for A/C-Type only (via built-in potentiometer). 2.23 ~ 4.45A |
|
VOLTAGE TOLERANCE Note.3 |
±1.0% |
|
LINE REGULATION |
±0.5% |
|
LOAD REGULATION |
±0.5% |
|
SETUP, RISE TIME Note.6 |
1000ms,80ms/115VAC |
|
HOLD UP TIME (Typ.) |
15ms / 115VAC, 230VAC |
|
INPUT |
VOLTAGE RANGE Note.5 |
90 ~ 305VAC |
FREQUENCY RANGE |
47 ~ 63Hz |
|
POWER FACTOR (Typ. |
PF 0.98/115VAC, PF 0.95/230VAC @ full load ≧ ≧ (Please refer to) |
|
TOTAL HARMONIC DISTORTION |
THD< 20% (@ load 50% / 115VAC,230VAC; @ load 75% / 277VAC) ≧ ≧ (Please refer to TOTAL HARMONIC DISTORTION (THD) section) |
|
EFFICIENCY (Typ.) |
93.5% |
|
AC CURRENT (Typ.) |
1.2A / 277VAC |
|
INRUSH CURRENT (Typ.) |
COLD START 75A(t =570 s measured at 50% I ) at 230VAC; width peak μ Per NEMA 410 |
|
MAX. No. of PSUs on 16A CIRCUIT BREAKER |
2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC |
|
LEAKAGE CURRENT |
<0.75mA / 277VAC |
|
PROTECTION |
OVER CURRENT |
95 ~ 108%, Constant current limiting, recovers automatically after fault condition is removed |
SHORT CIRCUIT |
Hiccup mode, recovers automatically after fault condition is removed |
|
OVER VOLTAGE |
60 ~ 67V. Shut down and latch off o/p voltage, re-power on to recover |
|
OVER TEMPERATURE |
Shut down o/p voltage, recovers automatically after temperature goes down |
|
ENVIROMENT |
WORKING HUMIDITY |
20 ~ 95% RH non-condensing |
STORAGE TEMP., HUMIDITY |
-40ºC ~ +80ºC, 10 ~ 95% RH |
|
TEMP. COEFFICIENT |
±℃ ℃ 0.03%/ (0 ~ 50 ) |
|
VIBRATION |
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes |
|
SAFETY & EMC |
SAFETY STANDARDS Note.8 |
UL1012, CAN/CSA-C22.2 No. 107.1-01, UL8750 (type”HL”), CSA C22.2 No. 250.0-08; TUV EN61347-1, EN61347-2-13 independent (except for HLG-240H C type); UL60950-1, UL8750, TUV EN60950-1; IP65 or IP67; J61347-1, J61347-2-13 approved |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level |
|
OTHERS |
MTBF |
207.9K hrs min. MIL-HDBK-217F (25ºC) |
DIMENSION |
251 x 68 x 38.8mm |
|
WEIGHT |
1.23kg |
Đang cập nhật...