Mr.Nguyễn Xuân Hà
Zalo 0969.393.232
Email: xuanha@havietpro.vn
Ms.Bùi Quỳnh Trang
Zalo 0962.726.399
Email: quynhtrang@havietpro.vn
Mr.Đinh Đức Huy
Zalo 0981.642.399
Email:duchuy@havietpro.vn
Mr.Lê Trần Đức Hải
Zalo 0867709588
Email:duchai@havietpro.vn
Ms.Trương Ngân Hà
Zalo 0978.851.059
Email: nganha@havietpro.vn
Ms.Ngô Thị Hà
Zalo 0961794588
Email: ngoha@havietpro.vn
Ms.Lê Hoàng Thảo Vy
Zalo 0961650488
Email: thaovy@havietpro.vn
Mr.Trần Quốc Bình
Zalo 0975.642.399
Email:quocbinh@havietpro.vn
Ms Dương Thị Ngọc Nhi
Zalo 0961591066
Email: ngocnhi@havietpro.vn
Zalo0962726399
Email:quynhtrang@havietpro.vn
Ms.Lê Trần Đức Hải
Email: duchai@havietpro.vn
Email:ngoha@havietpro.vn
Mr.Nguyễn Trung Hà
Zalo 0977.045.517
Email: trungha@havietpro.vn
Mr.Nguyễn Nam Thành
Zalo 0865647988
Email:namthanh@havietpro.vn
Email: info@havietpro.vn
Ms.Nguyễn Tuyết Nhung
Zalo0972697354
Ms.Ngọc Trân
Zalo 0786687714
Mr.Trương Tuấn Anh
Zalo 0975.919.955
Email:tuananh@havietpro.vn
Mr.Tạ Mạnh Hùng
Zalo 0964.365.399
Email:kythuathn.havietpro@gmail.com
Mr.Hoàng Quốc Hưng
Zalo 0961810788
Email:kythuathcm.havietpro@gmail.com
+ Di chuột để phóng to
Module cho đầu báo thường 1 zone NOHMI FRRU004-CIZM4
- The Conventional Initiating Zone Module (FRRU004-CIZM4) is used to supervise the status of conventional initiating devices connected on an Initiating device circuit (IDC). The FRRU004-CIZM4 detects an alarm condition and reports to the Fire Alarm Control Panel (FACP). The FRRU004-CIZM4 module also supervises the initiating device wiring (A+, A-, B+, and B- wires) and wiring for the power supply connected to terminals 24+ and 24- to detect an open circuit. IDC wiring style is applicable to the NFPA Class B (Style B) & Class A (Style D). When the FRRU004-CIZM4 module detects an alarm, the module is latched until the system reset. When the FRRU004-CIZM4 module is used with Class A (Style D) wiring condition and detects an open circuit on wiring of the IDC and power supply connected to terminal 24+ and 24-, the module is also latched until the system reset.
- The FRRU004-CIZM4 module has one red LED for local indication of the statuses of module itself and its wiring. Normal conditions are indicated by flashing LED. Alarm condition is indicated by constant illumination. Open circuit condition is indicated by extinction.
Features
- One simple LED for status indication.
- NFPA Class A (Styles 6 & 7) and Class B (Style 4) for SLC.
- NFPA Class A (Style D) and Class B (Style B) for IDC.
- Electronic address setting.
- Downsized unit.
- Easy installation.
Đặc tính kỹ thuật
Model FRRU004-CIZM4Rated voltage range of SLC input power (S+,S-) 22.0 to 24.0VMaximum SLC 24 VDC standby current (S+,S-) 250µAMaximum SLC 24 VDC alarm current (S+,S-) 1mAOperating voltage of external power supply line (24+,24-) 24VOutput voltage range of IDC (A+,A-,B+,B-) 15.7 to 22.6VMaximum module standby current of IDC 24 VDC (24+,24-) 8.5mA in Style B, 4.9mA in Style DMaximum detector standby current of IDC 24 VDC (24+,24-) 2.4mAMaximum module and detector alarm current of IDC 24 VDC (24+,24-) 50.0mAApplicable IDC wiring style Class A (Style D), Class B (Style B)Maximum wiring resistance of IDC 100ΩMaximum wiring capacitance of IDC 1µFEnd-of-line resistor for IDC in NFPA Style B wiring 5.1kΩ, 1/2WMaximum alarm reset voltage 0VMinimum alarm reset time 1.1 secondOperating temperature range 0°C to 49°C (32°F to 120°F)Operating humidity range 0 to 93% (non-condensing)Dimensions 106mm (4.17 inches) (H) × 106mm (4.17 inches) (W) × 29mm (1.14 inches) (DApplicable electrical box for installation North American 64mm (2-1/2 inches) deep 2-gang boxStandard 4 inches square box 38mm (1-1/2 inch) deep box
Đang cập nhật...
Giỏ hàng của bạn Có 0 sản phẩm
Hãy chọn tỉnh thành của bạn, bạn có thể thay đổi lại ở đầu trang
Số 64-B2 khu đô thị Đại Kim-Định Công,phường Định Công,TP Hà Nội.( có chỗ đỗ xe ô tô)Điện thoại: 024.36 878 666 - 0975 86 85 99
61/7 Bình Giã, phường Tân Bình, Thành phố Hồ Chí MinhĐiện thoại: 028.38 130 866 - 0975 86 85 99
Havietpro.vn - Siêu thị điện máy Văn Phòng