Mr.Nguyễn Xuân Hà
Zalo 0969.393.232
Email: xuanha@havietpro.vn
Ms.Bùi Quỳnh Trang
Zalo 0962.726.399
Email: quynhtrang@havietpro.vn
Mr.Đinh Đức Huy
Zalo 0981.642.399
Email:duchuy@havietpro.vn
Mr.Lê Trần Đức Hải
Zalo 0867709588
Email:duchai@havietpro.vn
Ms.Trương Ngân Hà
Zalo 0978.851.059
Email: nganha@havietpro.vn
Ms.Ngô Thị Hà
Zalo 0961794588
Email: ngoha@havietpro.vn
Ms.Lê Hoàng Thảo Vy
Zalo 0961650488
Email: thaovy@havietpro.vn
Mr.Trần Quốc Bình
Zalo 0975.642.399
Email:quocbinh@havietpro.vn
Ms Dương Thị Ngọc Nhi
Zalo 0961591066
Email: ngocnhi@havietpro.vn
Zalo0962726399
Email:quynhtrang@havietpro.vn
Ms.Lê Trần Đức Hải
Email: duchai@havietpro.vn
Email:ngoha@havietpro.vn
Mr.Nguyễn Trung Hà
Zalo 0977.045.517
Email: trungha@havietpro.vn
Mr.Nguyễn Nam Thành
Zalo 0865647988
Email:namthanh@havietpro.vn
Email: info@havietpro.vn
Ms.Nguyễn Tuyết Nhung
Zalo0972697354
Ms.Ngọc Trân
Zalo 0786687714
Mr.Trương Tuấn Anh
Zalo 0975.919.955
Email:tuananh@havietpro.vn
Mr.Tạ Mạnh Hùng
Zalo 0964.365.399
Email:kythuathn.havietpro@gmail.com
Mr.Hoàng Quốc Hưng
Zalo 0961810788
Email:kythuathcm.havietpro@gmail.com
+ Di chuột để phóng to
Module giám sát ngõ vào COFEM MSTAY
- Microprocessed algorithmic addressable device (with short-circuit isolator) installed as another element inside the loop.
- It has two inputs to distinguish between the open or close state of a dry contact connected in series with a 10 kΩ resistor. In quiescent condition, the contact has to be open, and in anomaly condition, the contact has to be closed. In the first input (marked with IN1), the closed contact is detected as an ALARM condition. In the second input (marked with IN2), the closed contact is detected as FAULT warning condition. It is possible to associate both inputs having an alarm and fault conditions information.
- In the quiescent condition, the device supervises the electrical connection through a 33kΩ resistor, which allows indication of open or closed electrical connection status.
- It is typically used to signal the status of other detection systems that may exist, as for example, connection of flow sensors in the case of sprinkler installations, end of travel in the case of fire-resistant doors, elevators, level of deposits, etc.
- The flashing of the transparent red LED indicates communication with the control panel, and if it remains lit, it indicates an alarm status. The illumination of the green LED indicates activation of one or both inputs.
- This device has an output for connection to a remote action indicator, which is activated when in alarm status. This element is electrical fed through the loop connection.
- The device is placed in a rectangular, heat-resistant ABS box.
- The module is certified according to EN 54-18 Standard, and CE mark according to the European Regulation of Construction Products (UE) N°305/2011.
Đặc tính kỹ thuật
Power Supply 24 - 35V with polarityStandby Current 1 mAShort-Circuit Isolator YesZone voltage 20V with polarityActivation Signal Red LightRemote Indicator Output YesHumidity 20 - 95% RHTemperature -10ºC +50ºCSize 140,5 x 73 x 48mmStandard EN 54-18IP Protection IP 30
Đang cập nhật...
Giỏ hàng của bạn Có 0 sản phẩm
Hãy chọn tỉnh thành của bạn, bạn có thể thay đổi lại ở đầu trang
Số 64-B2 khu đô thị Đại Kim-Định Công,phường Định Công,TP Hà Nội.( có chỗ đỗ xe ô tô)Điện thoại: 024.36 878 666 - 0975 86 85 99
61/7 Bình Giã, phường Tân Bình, Thành phố Hồ Chí MinhĐiện thoại: 028.38 130 866 - 0975 86 85 99
Havietpro.vn - Siêu thị điện máy Văn Phòng