Mr.Nguyễn Xuân Hà
Zalo 0969.393.232
Email: xuanha@havietpro.vn
Ms.Bùi Quỳnh Trang
Zalo 0962.726.399
Email: quynhtrang@havietpro.vn
Mr.Đinh Đức Huy
Zalo 0981.642.399
Email:duchuy@havietpro.vn
Mr.Lê Trần Đức Hải
Zalo 0867709588
Email:duchai@havietpro.vn
Ms.Trương Ngân Hà
Zalo 0978.851.059
Email: nganha@havietpro.vn
Ms.Ngô Thị Hà
Zalo 0961794588
Email: ngoha@havietpro.vn
Ms.Lê Hoàng Thảo Vy
Zalo 0961650488
Email: thaovy@havietpro.vn
Mr.Trần Quốc Bình
Zalo 0975.642.399
Email:quocbinh@havietpro.vn
Ms Dương Thị Ngọc Nhi
Zalo 0961591066
Email: ngocnhi@havietpro.vn
Zalo0962726399
Email:quynhtrang@havietpro.vn
Ms.Lê Trần Đức Hải
Email: duchai@havietpro.vn
Email:ngoha@havietpro.vn
Mr.Nguyễn Trung Hà
Zalo 0977.045.517
Email: trungha@havietpro.vn
Mr.Nguyễn Nam Thành
Zalo 0865647988
Email:namthanh@havietpro.vn
Email: info@havietpro.vn
Ms.Nguyễn Tuyết Nhung
Zalo0972697354
Ms.Ngọc Trân
Zalo 0786687714
Mr.Trương Tuấn Anh
Zalo 0975.919.955
Email:tuananh@havietpro.vn
Mr.Tạ Mạnh Hùng
Zalo 0964.365.399
Email:kythuathn.havietpro@gmail.com
Mr.Hoàng Quốc Hưng
Zalo 0961810788
Email:kythuathcm.havietpro@gmail.com
+ Di chuột để phóng to
Trung tâm báo cháy 2 Loop SIEMENS FC-1862/FC1861-A2
- FC1862 controller with 4 line card, max. 1008 points.
- Fulfill Chinese Standard of GB4717-2005 and GB16806-2006.
- Multi-language operation menu with windows style, easy and fast operation.
- Shortcut key (right key) for popping out operation items of device/event.
- Large memory space for up to 10000 history records, first in first out order, all events can be recorded during the operation period.
- LCD backlight Auto-off mode. When no operation or event to display within preset time, LCD backlight will be automatically turn off. When there are events / operations, LCD will light up automatically to display events and/or interlocking devices.
- 2 channels of programmable input/output (output: 40mA@24VDC, it can be programmed as general alarm output or general trouble output; input: dry contact).
- 1 channel of NAC for audible and visible device (0.5A@24VDC).
- 8 channels of interlocking function (output: 40mA @ 24VDC ) for automatic control and manual operations of control equipments.
- Efficient group programming according to different using.
- A FC186x controller can connect up to 2016 points by adding line card.
- Network bus (FC18-BUS), the max. distance is 1000m (the twist wiring capacity is 1.0 to 1.5 mm2). Up to 32 controllers can be networked.
- FRT bus (FR18-BUS), the max. distance is 1000m (the twist wiring capacity is 1.0 to 1.5 mm2). Up to 32 floor repeater displays can be networked.
- Detection bus (FD18-BUS), 2-wire polarity-free, the max. distance for line resistance is 4000m, the max. distance for line capacitance is 5000m. (the twist wiring capacity is 1.0 to 1.5 mm2)
- Three user levels for different operation authority. Each user level is accessed by a pre-defined and changeable password.
- Convenient pluggable terminals with clear marks for field wiring.
- Auto-mapping function to support on commissioning task.
- Detection algorithm can be adjusted by controller according to environment, to provide high reliability of alarm and reduce false alarm.
- Programming can be done either directly on controller or through computer.
- “Sticker Method” easy for commissioning on site.
Thông số ky thuật
Model FC-1862/'FC1861-A2Max. No. of line cards 8Max. No. of devices 2016LCD screen 320×240 pixels, backlitNo. of programmable input/ output on mainboard 2No. of NAC (0.5mA @24VDC) 1Max. history records 10000Max. distance between controllers within FC18-BUS 1000 mMax. No. of controllers networked within FC18-BUS 16Max. distance between a controller and a FRT/Mimic driver within FR18-BUS 1000 mMax. No of FRT/Mimic driver connected with a controller 32Auto-mapping function Available(only for detection line and field device)Battery (not included) Depends on local regulationCommunication interface Special converter moduleInput voltage 220 V@3A, 110 V@6A220 V/50Hz ,110 V/60HzPower supply capacity 10 A@24 VDCDimension (In: mm) 1000×600×200Weight (without battery) 34 KgPower fuse 220V:3.0 A , 110V:6.0ABattery fuse 10.0 A (DC)Operating temperature 0 ~ +40℃Storage temperature -10 ~ +50 ℃Humidity ≤95%(40±2 ℃)Environment requirement indoor
Đang cập nhật...
Giỏ hàng của bạn Có 0 sản phẩm
Hãy chọn tỉnh thành của bạn, bạn có thể thay đổi lại ở đầu trang
Số 64-B2 khu đô thị Đại Kim-Định Công,phường Định Công,TP Hà Nội.( có chỗ đỗ xe ô tô)Điện thoại: 024.36 878 666 - 0975 86 85 99
61/7 Bình Giã, phường Tân Bình, Thành phố Hồ Chí MinhĐiện thoại: 028.38 130 866 - 0975 86 85 99
Havietpro.vn - Siêu thị điện máy Văn Phòng