Mr.Nguyễn Xuân Hà
Zalo 0969.393.232
Email: xuanha@havietpro.vn
Ms.Bùi Quỳnh Trang
Zalo 0962.726.399
Email: quynhtrang@havietpro.vn
Mr.Đinh Đức Huy
Zalo 0981.642.399
Email:duchuy@havietpro.vn
Mr.Lê Trần Đức Hải
Zalo 0867709588
Email:duchai@havietpro.vn
Ms.Trương Ngân Hà
Zalo 0978.851.059
Email: nganha@havietpro.vn
Ms.Ngô Thị Hà
Zalo 0961794588
Email: ngoha@havietpro.vn
Ms.Lê Hoàng Thảo Vy
Zalo 0961650488
Email: thaovy@havietpro.vn
Mr.Trần Quốc Bình
Zalo 0975.642.399
Email:quocbinh@havietpro.vn
Ms Dương Thị Ngọc Nhi
Zalo 0961591066
Email: ngocnhi@havietpro.vn
Zalo0962726399
Email:quynhtrang@havietpro.vn
Ms.Lê Trần Đức Hải
Email: duchai@havietpro.vn
Email:ngoha@havietpro.vn
Mr.Nguyễn Trung Hà
Zalo 0977.045.517
Email: trungha@havietpro.vn
Mr.Nguyễn Nam Thành
Zalo 0865647988
Email:namthanh@havietpro.vn
Email: info@havietpro.vn
Ms.Nguyễn Tuyết Nhung
Zalo0972697354
Ms.Ngọc Trân
Zalo 0786687714
Mr.Trương Tuấn Anh
Zalo 0975.919.955
Email:tuananh@havietpro.vn
Mr.Tạ Mạnh Hùng
Zalo 0964.365.399
Email:kythuathn.havietpro@gmail.com
Mr.Hoàng Quốc Hưng
Zalo 0961810788
Email:kythuathcm.havietpro@gmail.com
+ Di chuột để phóng to
Tủ trung tâm chữa cháy CLVR 2 zones COFEM CLVR02EXT
- COFEM CLVR02EXT là tủ trung tâm điều khiển tự động hệ thường 2 zones với chức năng chữa cháy. Đạt tiêu chuẩn EN 54-2, EN 54-4, EN 12094-1 và CE mark.
Features
- 2 zones control panel with extinguishing functionality for conventional detectors and call points use.
- Third additional zone configurable as an alarm and detection zone for conventional detectors and call points or as a monitoring input of an external fire protection system.
- Same technical features as conventional CLVR control panels (2 general sounder outputs, 1 alarm output, 1 fault output, 230Vdc outputs, test mode, threshold setup, metallic cabinet, etc).
- 3 modes of operating extinction:
+ Standard mode: Output R1 of pre-warning is activated with Zone 1 or Zone 2 in alarm status.
+ Consecutive mode: Output R1 is activated intermittently (1 second with Zone 1 or Zone 2 in alarm status, 0,5 seconds with Zones 1 and 2 in alarm status, and continuing once the output R2 delay is finished).
+ Simultaneous mode: Output R1 is activated with Zones 1 and 2 in alarm status.
- Stop and activation extinguishing button directly in the control panel.
- Possibility to install manual stop and activation buttons near the flood zone.
- 1 extinction output (”R2”) supervised, temporized supervised, temporized between 0 and 60 seconds, protected by a resettable fuse.
- Delay for R2 extinguishing output reset after extinguishing activation temporized between 0 and 30 minutes.
- MODBUS protocol over RS485 on demand.
- Possibility of ON-LINE software in a PC using the MODBUS functionality.
- CONTACTID on demand.
- Certified according EN 54-2, EN 54-4 and EN 12094-1 with CE mark.
Đặc tính kỹ thuật
Model CLVR02EXTSupply voltage 110/230VAC 50/60HzOutput voltage 21 V NominalMax. consumption 70 VA at 230 V/ACBatteries 2x12V7 Ah SLAExtinction fuse R1/R2 0,5A/0,75A autoresetBatteries charger 500 mA 27 V/DC 20ºCDevices par zone 32Control panel power supply 2,2 AMax. current per zone 2 mA (in standby)End of line capacitor 4 K7Sounder output voltage 30 V/DCEnvironmentals conditions -10ºC +50ºCSize 363 x 331x96 mmWeight (without batteries) 4,3 KgStandard EN 54-2, EN 54-4&EN 12094-130v max. current output 1,5 AExtinction module fuse 1,85 A autoresetS1 output sounder fuse 1,85 A autoresetS2 output sounder fuse 0,75 A autoreset
Đang cập nhật...